Search results for "Electrode location"

showing 3 items of 3 documents

Variability in Lateral Positioning of Surface EMG Electrodes

2009

The positions of EMG electrodes over the knee extensor muscles were examined in 19 healthy men using MR images; electrodes were placed according to the SENIAM (surface electromyography for non-invasive assessment of muscles) guidelines. From axial images, the medial and lateral borders of the muscles were identified, and the arc length of the muscle surface was measured. The electrode location was expressed as a percentage value from the muscle’s medial border. EMGs were recorded during isometric maximal contraction, squat jumps, and countermovement jumps and analyzed for cross-correlation. The results showed that variations in lateral positioning were greatest in vastus medialis (47% SD 11…

AdultMaleMaterials scienceVastus medialisBiophysicsSquatIsometric exerciseElectromyographySensitivity and SpecificityIsometric ContractionmedicineHumansOrthopedics and Sports MedicineMaximal contractionMuscle SkeletalElectrodesmedicine.diagnostic_testElectromyographyRehabilitationLateral positioningReproducibility of ResultsAnatomymusculoskeletal systemElectrode locationElectrodePhysical EnduranceJournal of Applied Biomechanics
researchProduct

Effect of electrode location on surface electromyography changes due to eccentric elbow flexor exercise.

2009

Experiments were carried out to determine whether the location of electrodes has an effect on eccentric exercise–induced changes in surface electromyography (sEMG) variables in the biceps brachii muscle. sEMG signals were recorded with a grid of 64 electrodes before and up to 4 days post-exercise. Root mean square (RMS) and mean power frequency (MNF) were calculated for: (1) each channel; (2) as an average of all channels; and (3) as an average of individual channel rows and columns. Mean muscle-fiber conduction velocity (CV) was estimated similarly but was based on double-differential channels. Maximal isometric voluntary torque decreased 21.3 ± 5.6% post-exercise. The average sEMG variabl…

AdultMalePhysiologyMuscle Fibers SkeletalPainElectromyographyIsometric exerciseNerve conduction velocityRoot mean squareCellular and Molecular NeurosciencePhysiology (medical)Isometric ContractionmedicineElbowEccentricHumansMuscle SkeletalElectrodesExerciseMathematicsMuscle fatiguemedicine.diagnostic_testBiceps brachii muscleElectromyographySignal Processing Computer-AssistedAnatomyElectrode locationNeurology (clinical)Biomedical engineeringMuscle ContractionMusclenerve
researchProduct

Atrial Fibrosis Hampers Non-invasive Localization of Atrial Ectopic Foci From Multi-Electrode Signals: A 3D Simulation Study

2018

[EN] Introduction: Focal atrial tachycardia is commonly treated by radio frequency ablation with an acceptable long-term success. Although the location of ectopic foci tends to appear in specific hot-spots, they can be located virtually in any atrial region. Multi-electrode surface ECG systems allow acquiring dense body surface potential maps (BSPM) for non-invasive therapy planning of cardiac arrhythmia. However, the activation of the atria could be affected by fibrosis and therefore biomarkers based on BSPM need to take these effects into account. We aim to analyze the effect of fibrosis on a BSPM derived index, and its potential application to predict the location of ectopic foci in the …

Ectopic focus locationmedicine.medical_specialtyFocus (geometry)Physiologymedicine.medical_treatment0206 medical engineeringAtrial tachycardiaStructural remodelingBody surface potential map02 engineering and technologyOptimal electrode location030204 cardiovascular system & hematology3d simulationlcsh:PhysiologyTECNOLOGIA ELECTRONICA03 medical and health sciences0302 clinical medicineFibrosisPhysiology (medical)Internal medicineMedicineMachine-learningAtrial tachycardiaOriginal Researchlcsh:QP1-981business.industryCardiac electrophysiologyCardiac arrhythmiaTorsoAblationmedicine.disease020601 biomedical engineeringmedicine.anatomical_structureCardiologymedicine.symptombusinessFrontiers in Physiology
researchProduct